{
  "schema": "tnfr.organized-finite-window-design.method-sources.v1",
  "scope": "Primary method review for a supplied passive RC observation candidate with a finite output average, including loading, sensor state, clock and calibration obligations.",
  "owner": "theory/research/ORGANIZED_FINITE_WINDOW_DESIGN.md",
  "physical_dataset_selected": false,
  "measured_arrays_downloaded": false,
  "response_fit_performed": false,
  "reserved_response_evaluated": false,
  "physical_apparatus_admitted": false,
  "reviewed_on_local_date": "2026-10-11",
  "review_timezone": "Europe/Madrid",
  "review_scope": "Only the identified method and definition sections were reviewed. No source figure or response was selected as TNFR data. The earlier organized electrical feasibility receipt remains unchanged.",
  "provenance_scope": "Web text review only. No independently retrieved source bytes, archived source files or byte hashes are claimed. Source associations do not authenticate a physical calibration or establish the candidate model.",
  "sources": [
    {
      "id": "keithley-low-level-handbook-7",
      "title": "Keithley Low Level Measurements Handbook, 7th Edition",
      "source_type": "manufacturer_measurement_method_handbook",
      "canonical_url": "https://download.tek.com/document/LowLevelHandbook_7Ed.pdf",
      "requested_url": "https://download.tek.com/document/LowLevelHandbook_7Ed.pdf",
      "reviewed_sections": [
        "Section 2.2.1, printed pp. 2-3 to 2-4: input resistance and bias current",
        "Section 2.2.1, printed pp. 2-8 to 2-10: shunt capacitance loading and guarding",
        "Section 2.6.4, printed pp. 2-56 to 2-59: response speed, bandwidth and settling",
        "Section 3.2.8, printed pp. 3-12 to 3-13: line-cycle integration",
        "Sections 1.4.2 to 1.4.4, printed pp. 1-11 to 1-17: accuracy, uncertainty, drift and noise rejection"
      ],
      "factual_paraphrase": "Finite input resistance, bias current and instrument/cable capacitance load voltage measurements. The handbook models capacitive charging, transferred charge and bandwidth-dependent settling, while noting higher-order settling effects. It describes finite voltage integration and distinguishes accuracy, calibration conditions, probabilistic uncertainty, drift and noise rejection.",
      "inference_limits": "These methods motivate the supplied RC candidate; they do not certify its exact one-pole transfer, complete loaded matrix, sensor initialization, full C5 phase preparation or joint error bounds. The retained-state and finite-window consequences in the owner are our conditional derivations, not manufacturer claims.",
      "reviewed_on_local_date": "2026-10-11",
      "review_timezone": "Europe/Madrid",
      "review_status": "reviewed_primary_source_sections",
      "review_method": "web_source_text",
      "retrieval_status": "web_review_only",
      "direct_byte_retrieval_status": "not_attempted_for_this_receipt",
      "retrieved_at_utc": null,
      "bytes": null,
      "sha256": null,
      "optional_local_cache_path": null
    },
    {
      "id": "nist-si-section-2",
      "title": "NIST Special Publication 330, Section 2: The International System of Units",
      "source_type": "authoritative_SI_definition",
      "canonical_url": "https://www.nist.gov/pml/special-publication-330/sp-330-section-2",
      "requested_url": "https://www.nist.gov/pml/special-publication-330/sp-330-section-2",
      "reviewed_sections": [
        "Section 2.2, defining constants and Table 1",
        "Section 2.2.1, definition versus practical realization"
      ],
      "factual_paraphrase": "The SI fixes h=6.62607015e-34 joule seconds and e=1.602176634e-19 coulombs exactly. Defining a unit through a constant remains distinct from its practical realization.",
      "inference_limits": "The supplied constants support the reference conversion a0=h/(4*pi*e). They are not derived from TNFR and do not certify a Josephson realization, independent phase preparation, clock, loading or measurement calibration for the candidate apparatus.",
      "reviewed_on_local_date": "2026-10-11",
      "review_timezone": "Europe/Madrid",
      "review_status": "reviewed_primary_source_sections",
      "review_method": "web_source_text",
      "retrieval_status": "web_review_only",
      "direct_byte_retrieval_status": "not_attempted_for_this_receipt",
      "retrieved_at_utc": null,
      "bytes": null,
      "sha256": null,
      "optional_local_cache_path": null
    }
  ]
}
