  "schema": "tnfr.organized-electrical-feasibility.method-sources.v1",
  "scope": "Primary source, instrument and metrological-method review for independent preparation and measurement feasibility.",
  "owner": "theory/research/ORGANIZED_ELECTRICAL_FEASIBILITY.md",
  "physical_dataset_selected": false,
  "measured_arrays_downloaded": false,
  "response_fit_performed": false,
  "reserved_response_evaluated": false,
  "physical_apparatus_admitted": false,
  "checksum_scope": "Hashes associate the actually retrieved source bytes only. They do not authenticate the publisher, scientific claims, future source availability or calibration provenance.",
  "cache_scope": "Optional ignored local source cache. The receipt contains no source PDF, measurement array or reserved response; cached bytes are not a repository or test dependency.",
  "review_scope": "Section references identify the reviewed method and specification claims. Paper figures were not extracted or selected as TNFR data. Downloaded source bytes are separate from web text review.",
  "sources": [
    {
      "id": "babenko-2020",
      "title": "Babenko et al. (2020), Characterization of a Josephson Junction Comb Generator",
      "source_type": "primary_experimental_paper",
      "reviewed_sections": [
        "Printed p. 937, equations (1)-(2)",
        "Printed p. 938, chip layout and measurement procedure",
        "Printed p. 939, model discrepancies"
      ],
      "factual_paraphrase": "The RCSJ model supplies sinusoidal junction current and the voltage-phase row. The reported apparatus uses 1500 junctions, a 4 K chip and 5 GHz drive with separately calibrated measurements. The authors discuss nonsinusoidal behavior and junction variation as model discrepancies.",
      "scope_limit": "This apparatus does not supply the C5 component matrices, the TNFR acquisition history, preparation bounds or frozen error allowances.",
      "canonical_url": "https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=929317",
      "requested_url": "https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=929317",
      "resolved_url": "https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=929317",
      "reviewed_on_local_date": "2026-10-11",
      "review_timezone": "Europe/Madrid",
      "review_status": "reviewed_primary_source_sections",
      "review_method": "web_source_text",
      "retrieval_status": "retrieved_bytes",
      "retrieved_at_utc": "2026-10-10T22:35:14.909365+00:00",
      "bytes": 697995,
      "sha256": "b94bdd3f579aaab614a2981d7cd8e91af4dfeceff00e50d9f8594a4e119f7c90",
      "content_type": "application/pdf;charset=UTF-8",
      "optional_local_cache_path": "build/organized-electrical-feasibility/babenko-2020.pdf"
    },
    {
      "id": "english-2016-v2",
      "title": "English et al. (2016), Observation of non-sinusoidal current-phase relation in graphene Josephson junctions, arXiv:1305.0327v2",
      "source_type": "primary_experimental_paper",
      "reviewed_sections": [
        "PDF p. 1, apparatus and temperature",
        "PDF p. 2, equations (1)-(2) and nonhysteretic inference condition"
      ],
      "factual_paraphrase": "Phase-sensitive current-profile measurement uses a superconducting loop, flux transformer and DC SQUID. The refrigerator base temperature is 10 mK. The approximately 2 nH loop requires junction critical current below 135 nA for the stated nonhysteretic extraction regime.",
      "scope_limit": "The loop and transfer model do not certify noninvasive initialization or the TNFR constituent phase and formation bounds.",
      "canonical_url": "https://arxiv.org/pdf/1305.0327v2",
      "requested_url": "https://arxiv.org/pdf/1305.0327v2",
      "resolved_url": "https://arxiv.org/pdf/1305.0327v2",
      "reviewed_on_local_date": "2026-10-11",
      "review_timezone": "Europe/Madrid",
      "review_status": "reviewed_primary_source_sections",
      "review_method": "web_source_text",
      "retrieval_status": "retrieved_bytes",
      "retrieved_at_utc": "2026-10-10T22:35:14.910017+00:00",
      "bytes": 2360829,
      "sha256": "aba6d1314238ff3b3e57d4da992cd45123c7c08807739a0d5a56571ccb11db31",
      "content_type": "application/pdf",
      "optional_local_cache_path": "build/organized-electrical-feasibility/english-2016-v2.pdf"
    },
    {
      "id": "ah2700a-brochure",
      "title": "Andeen-Hagerling AH2700A capacitance bridge product brochure",
      "source_type": "manufacturer_specification",
      "reviewed_sections": [
        "PDF p. 1, selected performance specifications",
        "PDF p. 2, averaging, zero correction and cable correction"
      ],
      "factual_paraphrase": "The selected 1 kHz specifications list capacitance accuracy of plus or minus 5 ppm, stability below 1 ppm/year and temperature coefficient of plus or minus 0.035 ppm per degree Celsius. The brochure describes traceable calibration, fixture corrections and a speed-resolution tradeoff.",
      "scope_limit": "The published headline accuracy alone does not certify the frozen 0.01 ppm scalar box. Specialized calibration is not excluded, and calibration of the full cryogenic matrix remains separate.",
      "canonical_url": "https://www.andeen-hagerling.com/ah2700a.pdf",
      "requested_url": "https://www.andeen-hagerling.com/ah2700a.pdf",
      "resolved_url": "https://www.andeen-hagerling.com/ah2700a.pdf",
      "reviewed_on_local_date": "2026-10-11",
      "review_timezone": "Europe/Madrid",
      "review_status": "reviewed_primary_source_sections",
      "review_method": "web_source_text",
      "retrieval_status": "retrieved_bytes",
      "retrieved_at_utc": "2026-10-10T22:35:14.910476+00:00",
      "bytes": 314862,
      "sha256": "93c4d76224b9dd55b53cf17b66519f59aea4dbe23df79749b34637806381977b",
      "content_type": "application/pdf",
      "optional_local_cache_path": "build/organized-electrical-feasibility/ah2700a.pdf"
    },
    {
      "id": "nist-impedance",
      "title": "NIST, Farad and Impedance Metrology",
      "source_type": "primary_metrology_program_report",
      "reviewed_sections": [
        "Major Accomplishments, digital four-arm bridge comparison"
      ],
      "factual_paraphrase": "NIST reports a combined standard uncertainty of 5 parts per billion for a specialized comparison of a 100 kilohm resistor with a 1 nanofarad capacitor near 1592 Hz.",
      "scope_limit": "This prevents a universal claim that 1e-8 calibration is unattainable; it does not establish deterministic calibration of this complete assembly over its operating history.",
      "canonical_url": "https://www.nist.gov/programs-projects/farad-and-impedance-metrology",
      "requested_url": "https://www.nist.gov/programs-projects/farad-and-impedance-metrology",
      "resolved_url": "https://www.nist.gov/programs-projects/farad-and-impedance-metrology",
      "reviewed_on_local_date": "2026-10-11",
      "review_timezone": "Europe/Madrid",
      "review_status": "reviewed_primary_source_sections",
      "review_method": "web_source_text",
      "retrieval_status": "retrieved_bytes",
      "retrieved_at_utc": "2026-10-10T22:35:14.910854+00:00",
      "bytes": 89240,
      "sha256": "56d60818cc60566562e33ae2046d2711b00e427b144ea94908bcb30c8347f99a",
      "content_type": "text/html; charset=UTF-8",
      "optional_local_cache_path": "build/organized-electrical-feasibility/nist-impedance.html"
    },
    {
      "id": "jcgm-100-2008",
      "title": "JCGM 100:2008, Evaluation of measurement data - Guide to the expression of uncertainty in measurement",
      "source_type": "authoritative_metrology_guidance",
      "reviewed_sections": [
        "Section 2.3.5, printed p. 3",
        "Section 6.2, printed p. 23",
        "Section 7.2.5, printed p. 26"
      ],
      "factual_paraphrase": "Expanded uncertainty concerns an interval with coverage supported by distributional assumptions. Reporting multiple output estimates includes covariance information.",
      "scope_limit": "A confidence interval or RMS noise specification is not automatically a deterministic simultaneous bound for all 150 readings.",
      "canonical_url": "https://www.bipm.org/documents/20126/2071204/JCGM_100_2008_E.pdf",
      "requested_url": "https://www.bipm.org/documents/20126/2071204/JCGM_100_2008_E.pdf",
      "resolved_url": "https://www.bipm.org/documents/20126/2071204/JCGM_100_2008_E.pdf",
      "reviewed_on_local_date": "2026-10-11",
      "review_timezone": "Europe/Madrid",
      "review_status": "reviewed_primary_source_sections",
      "review_method": "web_source_text",
      "retrieval_status": "retrieved_bytes",
      "retrieved_at_utc": "2026-10-10T22:35:14.911212+00:00",
      "bytes": 1888806,
      "sha256": "41bbf068fbc0d7986c98691b2d1af6680cb3044f6a1a89b3560933ed9ef9626c",
      "content_type": "application/pdf",
      "optional_local_cache_path": "build/organized-electrical-feasibility/jcgm-100-2008.pdf"
    },
    {
      "id": "nist-si-section-2",
      "title": "NIST Special Publication 330, Section 2: The International System of Units",
      "source_type": "authoritative_SI_definition",
      "reviewed_sections": [
        "Section 2.2, definition of the SI and Table 1",
        "Section 2.2.1, definition versus realization"
      ],
      "factual_paraphrase": "The SI fixes h=6.62607015e-34 joule seconds and e=1.602176634e-19 coulombs exactly. Definition and practical realization are distinct.",
      "scope_limit": "These supplied physical constants support the reference value a0=h/(4*pi*e), not a derivation of h or e from TNFR or an exact apparatus calibration.",
      "canonical_url": "https://www.nist.gov/pml/special-publication-330/sp-330-section-2",
      "requested_url": "https://www.nist.gov/pml/special-publication-330/sp-330-section-2",
      "resolved_url": "https://www.nist.gov/pml/special-publication-330/sp-330-section-2",
      "reviewed_on_local_date": "2026-10-11",
      "review_timezone": "Europe/Madrid",
      "review_status": "reviewed_primary_source_sections",
      "review_method": "web_source_text",
      "retrieval_status": "retrieved_bytes",
      "retrieved_at_utc": "2026-10-10T22:35:14.911585+00:00",
      "bytes": 149876,
      "sha256": "52d3b20c14f75da2ea35ff9c41dc911e77dd42e00b4799c648fbf30c898af251",
      "content_type": "text/html; charset=UTF-8",
      "optional_local_cache_path": "build/organized-electrical-feasibility/nist-si-section-2.html"
    },
    {
      "id": "keithley-2182a-product-page",
      "title": "Tektronix / Keithley Model 2182A Nanovoltmeter product page",
      "source_type": "manufacturer_specification",
      "canonical_url": "https://www.tek.com/en/products/keithley/low-level-sensitive-and-specialty-instruments/nanovoltmeter-model-2182a",
      "requested_url": "https://www.tek.com/en/products/keithley/low-level-sensitive-and-specialty-instruments/nanovoltmeter-model-2182a",
      "resolved_url": null,
      "reviewed_on_local_date": "2026-10-11",
      "review_timezone": "Europe/Madrid",
      "review_status": "reviewed_primary_source_sections",
      "review_method": "web_source_text",
      "retrieval_status": "web_review_only",
      "direct_byte_retrieval_status": "not_attempted_for_this_receipt",
      "retrieved_at_utc": null,
      "bytes": null,
      "sha256": null,
      "content_type": null,
      "optional_local_cache_path": null,
      "reviewed_sections": [
        "Features and benefits, low noise and two-channel measurement"
      ],
      "factual_paraphrase": "The page describes two channels, 1 nV sensitivity and typical peak-to-peak noise of 15 nV at a 1 second response time, or 40 to 50 nV at 60 milliseconds.",
      "scope_limit": "Typical noise is magnitude context, not a deterministic lower bound. Response time does not by itself specify the inward positive averaging kernel required by the frozen protocol."
    }
  ],
  "unreviewed_sources": [
    {
      "id": "keithley-2182a-user-manual",
      "url": "https://download.tek.com/manual/2182A-900-01C_July_2022_User.pdf",
      "review_status": "not_reviewed",
      "retrieval_status": "unavailable",
      "reported_failure": "Coordinating review encountered HTTP 403 for direct retrieval and unsupported content type through web access.",
      "bytes": null,
      "sha256": null,